<u id="jaukx"></u>

<pre id="jaukx"></pre>

  1. <form id="jaukx"></form>
    1. 亚洲中文字幕久久无码精品,亚洲中文字幕AV无码专区,久久99久国产精品66,成人爽A毛片在线视频淮北,四虎成人久久精品无码,欧美区在线播放,欧美老熟妇com,久久精品亚州中文字幕

      產(chǎn)品分類(lèi)

      Products

      技術(shù)文章/ ARTICLE

      我的位置:首頁(yè)  >  技術(shù)文章  >  ASJ系列剩余電流動(dòng)作繼電器

      ASJ系列剩余電流動(dòng)作繼電器

      更新時(shí)間:2022-11-21      瀏覽次數(shù):1058

      安科瑞 陳聰

      ASJ series Residual Current Action Relay

      1. 概述

      Overview

      在工業(yè)應(yīng)用中,剩余電流繼電器與外部剩余電流互感器結(jié)合使用以檢測(cè)和評(píng)估接地故障電流。它們也可以與保護(hù)裝置結(jié)合使用,以實(shí)現(xiàn)電路的斷開(kāi),從而實(shí)現(xiàn)對(duì)線(xiàn)路和人員的保護(hù)。

      Residual current relay can be combined with external residual current transformer to detect and evaluate the ground fault current. They can also be combined with protective devices to realize the disconnection of circuits and the protection of lines and workers.

      2.剩余電流的定義以及危害

      Definition and risk of residual current

      剩余電流,是指低壓配電線(xiàn)路中各相(含中性線(xiàn))電流矢量和不為零的電流。通俗講當(dāng)用電側(cè)發(fā)生了事故,電流從帶電體通過(guò)人體流到大地,使主電路進(jìn)出線(xiàn)中的電流I相和I中的大小不相等,此時(shí)電流的瞬時(shí)矢量合成有效值稱(chēng)為剩余電流,俗稱(chēng)漏電。

      Residual current is the current vector sum of each phase (including the neutral ) in the low-voltage distribution that not be zero. Generally, when there is an accident on the power side, the current flows from the charged body to the earth through the human body,it will cause that the current phase I in the main circuit not equal to the size in phase I. At this time, the value of instantaneous current vector synthesis is called residual current, commonly known as leakage.

      TN System

       

      1.png


      3.剩余電流的危害:

      Risk of residual current:

      人身觸電。當(dāng)電氣設(shè)備因絕緣損壞而使外殼帶電,而工作人員又接觸此外殼時(shí),就會(huì)導(dǎo)致人身觸電事故。

      (1)Physical electric shock. When shell of the electrical equipment is electrified due to insulation damage, and the workers touch the shell again, it will lead to physical electric shock accident.

      燒損電氣設(shè)備,引起火災(zāi)。長(zhǎng)期存在的漏電電流,尤其是兩相經(jīng)過(guò)電阻接地的漏電電流,在通過(guò)設(shè)備絕緣損壞處時(shí)將散發(fā)出大量的熱,使絕緣進(jìn)一步損壞,甚至使可燃性材料(如非阻燃性橡套電纜)著火燃燒。

      Burn electrical equipment and cause fire. The long-term leakage current, especially the leakage current of  two-phase grounded through resistance, will release a lot of heat when flow through the damaged part of the equipment insulation, further damaging the insulation, and even making combustible materials (such as non flame retardant rubber sheathed cable) burn on fire.

      引起短路事故。據(jù)統(tǒng)計(jì),約有30%的單相接地故障發(fā)展為短路。從而造成更大的電氣故障。長(zhǎng)期存在的漏電電流及電火花使漏電處的絕緣進(jìn)一步損壞,后危及相間絕緣而造成短路。

      (3) Cause short circuit accident. According to statistics, about 30% of single-phase grounded faults develop into short circuit which will give rise to heavier electrical failure. The long-term leakage current and spark further damage the insulation at the leakage point, and finally endanger the interphase insulation and cause short circuit.

      引起電氣火災(zāi)事故。電網(wǎng)發(fā)生單相接地或設(shè)備發(fā)生單相碰殼時(shí),在接地點(diǎn)就會(huì)產(chǎn)生電火花,若此電火花具有足夠的能量,就可能點(diǎn)燃易燃易爆物品。

      Cause electrical fire accident. When the single-phase grounding occurs in the power grid or the single-phase collision occurs in the equipment, the electric spark will be generated at the grounding point. If the electric spark has enough energy, it may ignite flammable and explosive materials.

      4.如何測(cè)剩余電流

      How to measure residual current

      在被測(cè)的三相導(dǎo)線(xiàn)路上與N線(xiàn)上各裝一個(gè)CT,或讓三相導(dǎo)線(xiàn)與N線(xiàn)一起穿過(guò)一個(gè)零序CT,得到三相導(dǎo)線(xiàn)與中性線(xiàn)N的電流矢量和IA*+IB*+IC*+IN*,當(dāng)沒(méi)有發(fā)生單相接地故障時(shí),無(wú)論三相負(fù)荷平衡與否,則此矢量和為零;當(dāng)發(fā)生某一相接地故障時(shí),故障電流中會(huì)通過(guò)保護(hù)PE及與地相關(guān)連的金屬構(gòu)件回到電源,即IA*+IB*+IC*+IN*,此時(shí)數(shù)值為接地故障電流Id。

      Installing a CT on each of the three-phase conducting lines to be tested and N line or let the three-phase conductor and the n-line pass through a zero sequence CT together to get the current vector sum IA * + IB * + IC * + IN * . when there is no single-phase grounded fault, whether the three-phase load is balanced or not, the vector sum is zero; when there is a phase grounded fault, the fault current will flow through the protection PE and the metal components connected to the earth to the power supply, at this time, the value is the ground fault current Id.


      5.ASJ系列剩余電流動(dòng)作繼電器

      ASJ series residual current operated relay

      ASJ系列剩余電流動(dòng)作繼電器可與低壓斷路器或低壓接觸器等組成組合式剩余電流保護(hù)裝置, 主要適用于交流 50Hz, 額定電壓 400V 及以下的 TT 和 TN 系統(tǒng)配電線(xiàn)路, 用來(lái)對(duì)電氣線(xiàn)路進(jìn)行接地故障保護(hù), 防止接地故障電流引起的設(shè)備損壞和電氣火災(zāi)事故, 也可用來(lái)對(duì)人身觸電危險(xiǎn)提供間接接觸保護(hù)。

      ASJ series residual current action relay can be combined with low voltage circuit breaker or low voltage contactor to form a combined residual current protection device.It is mainly used for TT and TN system distribution lines with AC 50Hz and rated voltage of 400V and below.It is used to protect the electrical circuit from ground faults, prevent equipment damage caused by ground fault current and electrical fire accidents, and can also be used to provide indirect contact protection against personal electric shock hazard

      4.png

      5.png

      6.png

      7.png


      參考文獻(xiàn) Bibliography

      1.Solutions For Enterprise Micro-grid System 2020.02


      蘇公網(wǎng)安備 32028102001251號(hào)

      主站蜘蛛池模板: 久久久久亚洲精品无码网址| 亚洲精品成人网站在线播放| gogogo高清在线观看视频中文| 99re在线观看视频| 我把寡妇日出水了| 黄片的全部视频在线观看| 色综合热无码热国产| 久久精品人人做人人爽97| 国产精品一区二区三区卡| 亚洲第一福利网站在线观看| 国产成人AV性色在线影院| 久久精品久久电影免费理论片| 日本高清www午色夜免费观看| 国产福利在线免费观看| 91在线视频视频在线| 亚洲综合小说另类图片五月天 | 国产黄色精品高潮播放| 2021久久超碰国产精品最新| 人人妻人人澡人人爽人人精品| 亚洲三级a| 国产精品18久久久久久不卡中国| 国产旡码高清一区二区三区| 欧美日韩北条麻妃一区二区| 成全大全免费观看完整版高清下载 | japanesehd熟女熟妇| 亚洲中文字幕国产综合| 日韩欧美第一区二区三区| 九九热这里都是精品| 国产一区在线观看视频| 久色精品国产亚洲av麻豆一| 欧美精品啪啪| 亚洲av高清在线观看三区| 国产精品无码av天天爽播放器| 人妻熟女一区二区av| 男人女人午夜视频免费| 色久悠悠婷婷综合在线亚洲| 天啦噜国产精品亚洲精品| 狠狠热精品免费观看| 国产在线视频二区| 国产精自产拍久久久久久蜜| av无码东京热亚洲男人的天堂 |